Temperature sensors based on precious metals demonstrate outstanding resistance to corrosion, thus guaranteeing long service life and reliable measurement accuracy.
For measuring high temperatures of up to 1700°C, thermocouple wires made of high-purity platinum or platinum/rhodium alloys are therefore the solution. The thermocouples made of these wires are used for measuring exact temperatures in the steel and semiconductor industries, for example.
Thermocouple wires from Ravindra Heraeus are distinguished by their particularly high purity and demonstrate outstanding long-term stability.
Thermocouple wires from Ravindra Heraeus offer a solution for exact measurement results for the thermocouple in a corrosive environment. The precious metal wires withstand temperature measurements from 800 to 1700°C.
Depending on the specific application, metallurgical composition for the optimization of heat control such as in electrically heated steel furnaces and for manufacturing high temperature sensors used in foundries and in steel making
Temperature measurement in siphons or feeders using rod sensors with three or five measurement points: Manufacturing roof and floor sensors for glass melting furnaces in the direct melting or boosting processes
Depending on the specific application, metallurgical composition for the optimization of heat control such as in electrically heated hardening furnaces: Manufacturing high temperature sensors in metal processing
Contact sensors for open flames: Manufacturing temperature sensors with K1 approval in accordance with EDF technology for use in the primary circuits of nuclear power stations, temperature sensors in conventionally fired boilers
Manufacturing vibration resistant mechanical temperature sensors in vehicles for use on land, on water, and in the air
For all production steps with special hygiene regulations: Manufacturing temperature regulators resistant to humidity and pressure
Manufacturing spikes for the semiconductor industry, temperature measurement in the diffusion treatment of wafers
Calibration equipment such as furnaces, probes, and triple-point cells
For the measurement of temperatures in pressure vessels, pipelines, etc.: Manufacturing rod sensors in single, double, or multiple-point versions
Tolerance classes | In each case, the higher value is applicable [t = temperature in °C] |
---|---|
Class 1 | ± 1 °C or ± {1 + (t - 1100) x 0.003} °C |
Class 2 | ± 1.5°C or ± {0,0025 x t} °C |
Type | Class 1 | Class 2 |
---|---|---|
S | X | X |
R | X | X |
B | X |
The temperature scale used in IPTS 1968 with the following fixed points: | |
---|---|
zinc point | 419.58°C |
gold point | 1064.43°C |
palladium point | 1554°C |
platinum point | 1769°C |
Ravindra Heraeus Pvt. Limited
A -196 (A), F Road, Madri Industrial Area,
Udaipur - 313001, India.
Phone - +91-294-6644222, 2490029
Fax - +91-294-2492177, 2491825
sales@ravindraheraeus.com